- Describe the main uses of AI in medical imaging, clinical decision support, clinical documentation, drug discovery and scientific research.
- Explain how AI medical software is regulated in the US (510(k), De Novo, PMA, change control plans) and the EU (MDR, notified bodies, the AI Act's high-risk layer).
- Calculate sensitivity, specificity and predictive values, and show how prevalence changes the meaning of a positive result.
- Compare levels of clinical evidence, from retrospective test sets to randomised trials and post-market monitoring.
- Implement external and subgroup validation with bootstrap confidence intervals.
- Assess scientific AI results such as AlphaFold, learned weather models and materials predictions against experimental evidence standards.
Before this: Model Evaluation and Metrics, Bias and Fairness in AI
Medicine and science are where AI's promise and its failure modes are both at their sharpest. A model that reads chest X-rays, flags sepsis or predicts a protein's shape can save time and lives, but a model that quietly performs worse on one hospital's scanner or one group of patients can cause harm at scale. This lesson covers what AI does in these fields today, how it is regulated, and, most importantly, what evidence you should demand before trusting it.
This lesson is general education, not medical or regulatory advice. Regulatory details change; check the official sources listed before relying on them.
The intuition: a new instrument, not a new doctor
Think of a clinical AI model as a new laboratory instrument, like a blood analyser. Nobody asks whether a blood analyser is "intelligent". They ask: what exactly does it measure, how accurate is it, on which samples was that accuracy established, how does it drift over time, and what happens to patients when it is wrong? The same questions, asked with the same discipline, cut through most of the hype around medical AI. The instrument framing also explains why regulators treat much clinical AI software as a medical device: its output influences diagnosis or treatment, so it must show it is safe and effective for a stated purpose.
Science adds a second picture: AI as a very fast, very cheap hypothesis generator. AlphaFold proposes protein structures; graph networks propose stable crystals; learned weather models propose tomorrow's atmosphere. Each proposal is valuable only to the degree that it is checked against experiment or observation.
Where AI is used in healthcare
Medical imaging
Imaging is the most mature area because it fits supervised learning well: large archives of labelled images, a well-defined output (a finding, a measurement, a triage priority), and a clinician already in the loop. Typical functions are:
- Detection and triage: flagging suspected findings such as a brain bleed on CT or a lung nodule, and moving those studies up the reading queue.
- Measurement and segmentation: outlining organs or tumours and computing volumes, which is tedious and variable when done by hand.
- Screening support: acting as a second reader in programmes like mammography, or reading retinal photographs for diabetic retinopathy.
An important milestone was IDx-DR (now LumineticsCore), which the US Food and Drug Administration (FDA) authorised in 2018 as the first autonomous AI diagnostic system: it outputs a referral decision for diabetic retinopathy without a clinician interpreting the image. The pivotal study was prospective, ran in primary-care clinics and pre-specified its endpoints, which is exactly the kind of evidence that should be the norm.
Prospective trials of AI in screening are now appearing. The Swedish MASAI randomised trial (Lång et al., Lancet Oncology, 2023) reported in its interim safety analysis that AI-supported mammography screening found about 20% more cancers than standard double reading while cutting the radiologists' screen-reading workload by about 44%, with a similar false-positive rate. The trial's primary endpoint, interval cancers (cancers diagnosed between screening rounds), was reported in The Lancet in January 2026: about 12% fewer interval cancers in the AI-supported arm (82 versus 93 among roughly 106,000 women). The design (randomised, prospective, real screening population, a clinically meaningful endpoint) is the right one.
Clinical decision support and risk prediction
Clinical decision support (CDS) means software that gives clinicians patient-specific information or recommendations: drug-interaction alerts, deterioration scores, sepsis warnings, readmission risk. Risk models built on electronic health record (EHR) data are widespread, and they are where several cautionary tales come from:
- External validation failure. Wong et al. (JAMA Internal Medicine, 2021) evaluated a widely deployed proprietary sepsis model at Michigan Medicine and found an area under the ROC curve of 0.63, well below the developer's reported performance, with the model missing most sepsis cases while generating many alerts.
- Label bias. Obermeyer et al. (Science, 2019) showed that a commercial algorithm used to allocate extra care used healthcare cost as its training label. Because less money had historically been spent on Black patients with the same level of illness, the model systematically underestimated their needs. The algorithm was accurate at predicting its label; the label was the wrong proxy for need.
The lesson from both: a model can be technically sound and still be harmful when the data, label or deployment setting differs from what was validated.
Language models in clinical documentation
Large language models (LLMs) are moving fastest in administrative and documentation work, where errors are easier to catch than in diagnosis:
- Ambient scribes record (with consent) the clinician-patient conversation, transcribe it, and draft a structured note for the clinician to edit and sign.
- Draft replies to patient portal messages, discharge summaries, referral letters and prior-authorisation paperwork.
- Summarisation of long records and coding support.
The risks are specific: omissions (a symptom mentioned but not recorded), hallucinated content (an examination finding that never happened), wrong attribution (the patient's words recorded as the clinician's assessment), and automation complacency, where busy clinicians sign drafts they skimmed. Evidence so far focuses on clinician time, burnout and note quality; evidence on patient outcomes is thinner. A sound deployment measures error rates on audited samples, not just satisfaction surveys, and keeps the clinician as the accountable author.
Regulation in brief
United States
The FDA regulates software that meets the definition of a medical device, often called Software as a Medical Device (SaMD). Most AI devices reach the market through one of three pathways: 510(k) clearance (showing substantial equivalence to an existing "predicate" device), De Novo classification (for novel low-to-moderate-risk devices with no predicate), or premarket approval (PMA) for the highest-risk devices. Most AI devices have come through 510(k).
The FDA publishes a public list of AI-enabled medical devices authorised for marketing in the US and updates it periodically. The list grew past 1,000 devices by 2025, and radiology accounts for a large majority of entries, followed at a distance by cardiology and neurology. Check the FDA page for the current total; the count changes with every update.
Two regulatory ideas matter for engineers:
- Locked versus adaptive models. Traditionally a device's algorithm is fixed at authorisation, and significant changes need a new submission. That clashes with the ML habit of retraining.
- Predetermined Change Control Plans (PCCPs). The FDA finalised guidance on 4 December 2024 allowing manufacturers to describe in advance which model modifications they plan (for example, retraining on new data within defined bounds), how they will validate them, and how they will assess impact, so authorised changes can be made without a new submission.
Not all clinical software is a device. Some CDS that shows its basis to a clinician who can independently review it falls outside device regulation under criteria in the 21st Century Cures Act and FDA guidance. Where that line falls for LLM-based tools is an active question.
European Union
In the EU, medical device software falls under the Medical Device Regulation (MDR, Regulation (EU) 2017/745), which applied from 26 May 2021, and the In Vitro Diagnostic Regulation (IVDR) for diagnostic tests. Software that informs diagnosis or therapy is typically class IIa or higher under MDR's software rule, which means a notified body (an independent assessment organisation) must review it before it can carry the CE mark. MDR requires clinical evaluation, post-market surveillance and a quality management system.
The EU AI Act adds a second layer: AI that is a safety component of, or is itself, a product requiring third-party assessment under MDR or IVDR is classed as high-risk. As of November 2026, after the "Digital Omnibus" amendments (in force since 27 July 2026), the high-risk obligations for AI embedded in such regulated products apply from 2 August 2028 (see AI Law and Regulation).
Clinical validation: the evidence ladder
A useful way to judge a clinical AI claim is to ask how far up this ladder the evidence climbs:
| Level | Question answered | Typical evidence |
|---|---|---|
| 1. Technical | Does it discriminate on held-out data from the same source? | Retrospective test split; AUROC, sensitivity, specificity |
| 2. External | Does it hold up at other sites, scanners, populations? | Retrospective multi-site validation, subgroup analysis |
| 3. Prospective | Does it work in real time on new patients, in the workflow? | Silent-mode or prospective cohort studies |
| 4. Impact | Does using it improve decisions or outcomes? | Randomised or stepped-wedge trials |
| 5. Post-market | Does it keep working as practice and data drift? | Monitoring, audits, incident reporting |
Most published medical AI sits at level 1 or 2. Reporting guidelines exist to make studies comparable: TRIPOD+AI for prediction-model studies, CONSORT-AI and SPIRIT-AI for trials and trial protocols involving AI, and DECIDE-AI for early-stage clinical evaluation.
Metrics that matter, and why prevalence changes everything
Let sensitivity (the share of sick patients flagged), specificity (the share of healthy patients cleared), and positive predictive value (the share of flags that are real). By Bayes' rule, with prevalence , sensitivity and specificity :
Sensitivity and specificity are properties of the test (if the population's case mix is similar); PPV depends heavily on prevalence.
Worked example. An AI screening tool has sensitivity 0.90 and specificity 0.95.
Screening population, prevalence 0.6%. Take 100,000 people. Diseased: . True positives: ; false negatives: 60. Healthy: 99,400. False positives: ; true negatives: 94,430.
Fewer than 1 in 10 flags is a real case. Negative predictive value is .
Specialist clinic, prevalence 20%. Diseased: 20,000; true positives 18,000. Healthy: 80,000; false positives 4,000. PPV .
The same model goes from "mostly false alarms" to "mostly right" purely because of where it is used. That is why a vendor's accuracy figure means little without the setting in which it was measured, and why alert fatigue is a predictable consequence of deploying sensitive models in low-prevalence populations.
Calibration matters too: if a model says 30% risk, about 30% of such patients should have the outcome. A common summary is the Brier score, , where is the predicted probability and the outcome. Discrimination (AUROC) can survive a move to a new hospital while calibration and alert volume change sharply.
Code: internal versus external validation with subgroups
The sketch below trains a model at one synthetic "hospital", then evaluates it on a held-out split from the same site and on a second site where one feature is shifted (as a new lab assay or scanner might do). It reports AUROC with a bootstrap 95% confidence interval, the alert rate at a fixed threshold, and sensitivity in a subgroup where the signal is weaker.
import numpy as np
from sklearn.linear_model import LogisticRegression
from sklearn.metrics import roc_auc_score
rng = np.random.default_rng(0)
def make_site(n, shift, prev):
y = rng.random(n) < prev
X = rng.normal(size=(n, 5))
X[:, 0] += 1.2 * y
X[:, 1] += 0.8 * y + shift # shift mimics a new scanner or assay
group = rng.random(n) < 0.3 # a minority subgroup
X[group, 0] -= 0.6 * y[group] # weaker signal in that subgroup
return X, y.astype(int), group
Xa, ya, ga = make_site(5000, shift=0.0, prev=0.10) # development site
Xb, yb, gb = make_site(5000, shift=1.0, prev=0.10) # external site
tr = np.arange(5000) < 3500 # 70/30 split at site A
model = LogisticRegression(max_iter=1000).fit(Xa[tr], ya[tr])
def boot_auc(y, p, n_boot=1000):
aucs = []
for _ in range(n_boot):
s = rng.choice(len(y), len(y), replace=True)
if y[s].min() != y[s].max():
aucs.append(roc_auc_score(y[s], p[s]))
return np.percentile(aucs, [2.5, 97.5])
thr = np.quantile(model.predict_proba(Xa[tr])[:, 1], 0.85) # flag top 15%
for name, X, y, g in [("internal", Xa[~tr], ya[~tr], ga[~tr]),
("external", Xb, yb, gb)]:
p = model.predict_proba(X)[:, 1]
lo, hi = boot_auc(y, p)
flag = p >= thr
print(f"{name}: AUROC={roc_auc_score(y, p):.3f} ({lo:.3f}-{hi:.3f}) "
f"alert rate={flag.mean():.2f}")
for label, m in [("majority", ~g), ("subgroup", g)]:
print(f" {label} sensitivity={flag[m & (y == 1)].mean():.2f}")
On a typical run, AUROC is about 0.80 at both sites, yet the alert rate at the external site roughly doubles (from about 0.16 to about 0.29) because the shifted feature pushes everyone's scores up, and subgroup sensitivity trails the majority at both sites. A single headline AUROC would have hidden both problems: the doubled workload for clinicians and the gap for the subgroup.
Bias and equity
Sources of bias in clinical AI include unrepresentative training data (for example, dermatology images dominated by lighter skin), label bias (the Obermeyer cost-as-need problem), measurement bias (devices such as pulse oximeters that read less accurately on darker skin feed biased inputs), and access bias (patients who rarely see doctors have sparse records, so models know less about them). Mitigation starts with measuring performance by subgroup with confidence intervals, choosing labels that reflect the clinical goal, and monitoring after deployment. See Bias and Fairness.
AI in drug discovery and protein structure
AlphaFold
Predicting a protein's 3D shape from its amino-acid sequence was a 50-year grand challenge. At the CASP14 assessment in 2020, DeepMind's AlphaFold 2 produced predictions with accuracy competitive with experimental structures for a large share of targets, and the method was published in Nature in 2021 (Jumper et al.). DeepMind and EMBL's European Bioinformatics Institute then released the AlphaFold Protein Structure Database, which expanded in 2022 to over 200 million predicted structures, covering nearly every catalogued protein. AlphaFold 3 (Abramson et al., Nature, 2024) extended prediction to complexes of proteins with DNA, RNA, small-molecule ligands and ions. The 2024 Nobel Prize in Chemistry was awarded half to David Baker for computational protein design and half jointly to Demis Hassabis and John Jumper for protein structure prediction.
Know the limits. AlphaFold predicts a static structure, not the full range of motion a protein goes through; its own per-residue confidence score (pLDDT) is low for disordered regions; and a predicted structure is a hypothesis that still needs experimental confirmation for high-stakes uses such as drug design.
The drug pipeline
AI is used along the pipeline: target identification from genomic and literature data, virtual screening of huge compound libraries, generative design of molecules with desired properties, prediction of absorption, toxicity and other properties, and trial design and patient matching. Several AI-derived candidates have entered human trials. The honest evaluation standard is the same as for any drug: phase transition rates and approvals, not press releases about how fast a candidate was nominated. Discovery speed matters less if most failures happen later, in clinical trials, for reasons such as efficacy and safety that early models do not capture well.
AI for science more broadly
- Weather forecasting. Learned models trained on decades of reanalysis data now rival physics-based forecasts for many variables. DeepMind's GraphCast (Lam et al., Science, 2023) produced 10-day global forecasts in under a minute on a single accelerator and outperformed the European Centre for Medium-Range Weather Forecasts' (ECMWF) high-resolution deterministic forecast on about 90% of the targets it evaluated. GenCast (Price et al., Nature, 2024) extended this to probabilistic ensemble forecasts. ECMWF itself made its learned Artificial Intelligence Forecasting System (AIFS) operational on 25 February 2025, running alongside its physics-based model. These models still rely on physics-based data assimilation to produce their starting conditions.
- Materials discovery. DeepMind's GNoME (Merchant et al., Nature, 2023) used graph neural networks to predict about 2.2 million new crystal structures, of which about 380,000 were predicted to be stable. A companion paper described an autonomous lab synthesising new compounds; independent researchers later disputed whether some of those materials were genuinely new and correctly characterised. The episode is a useful case study: a computational "discovery" is a candidate until it is synthesised, characterised and independently confirmed.
- Other areas include fusion plasma control, mathematics (searching for counterexamples and constructions), and automated analysis of telescope and particle-detector data.
Common pitfalls
- Data leakage across patients. Splitting by image instead of by patient lets the same patient appear in training and test sets, inflating results. Split by patient, and for time-dependent problems, by time.
- Shortcut learning. Models learn hospital-specific artefacts (scanner text markers, portable versus fixed X-ray machines, the presence of a chest drain that signals treatment has already happened) instead of disease.
- Reporting accuracy on imbalanced data. With 1% prevalence, "always negative" is 99% accurate. Report sensitivity, specificity, PPV at a realistic prevalence, calibration and confidence intervals.
- Ignoring the workflow. A model that adds alerts without changing who acts on them, and how, rarely improves outcomes.
- No post-deployment monitoring. Case mix, coding practices and equipment change; performance silently decays.
- Treating a predicted structure or material as a result. Computational outputs are hypotheses until verified experimentally.
In practice
- Define the intended use precisely: which patients, which setting, which decision, which user. Regulation and validation both hang on this.
- Climb the evidence ladder: external validation across sites and subgroups before any deployment; a silent-mode prospective run (the model predicts but no one sees the output) before go-live.
- Measure in the units clinicians feel: alerts per shift, number needed to evaluate (), minutes saved, errors found in audited notes.
- Plan change control: version models, document retraining triggers and validation steps, and align with PCCP-style processes where they apply.
- Keep accountability with clinicians for LLM-drafted documentation, and audit samples regularly for omissions and fabrications.
- For science applications, build an experimental confirmation step into every pipeline, and report the hit rate of computational predictions, not just their number.
Key takeaways
- Treat clinical AI like a new instrument: define its intended use and demand evidence from the setting where it will be used.
- Positive predictive value depends heavily on prevalence, so the same model can produce mostly false alarms in screening and mostly true alerts in a specialist clinic.
- External validation, subgroup analysis and post-deployment monitoring catch failures that a single internal AUROC hides.
- In the US most AI devices reach the market through 510(k), and change control plans let manufacturers pre-specify how models will be updated; in the EU, MDR and the AI Act apply together.
- AlphaFold, learned weather models and materials-discovery models are powerful hypothesis generators whose outputs still need experimental or observational confirmation.
- LLM documentation tools save time but need audited error rates and an accountable clinician signing every note.
Terms in this lesson
- Software as a Medical Device (SaMD)
- Software intended for a medical purpose, such as diagnosis or treatment, that performs that purpose without being part of a hardware medical device.
- 510(k)
- A US FDA premarket pathway in which a manufacturer shows that a new device is substantially equivalent to a legally marketed predicate device.
- De Novo classification
- A US FDA pathway for novel low-to-moderate-risk devices that have no suitable predicate.
- Predetermined Change Control Plan (PCCP)
- A plan, authorised with a device, that specifies which future model modifications are intended and how they will be validated, so they can be made without a new submission.
- Notified body
- An independent organisation designated by an EU member state to assess whether medium- and high-risk medical devices conform to the MDR before CE marking.
- Positive predictive value (PPV)
- The proportion of positive test results that are true positives, which depends on both test accuracy and disease prevalence.
- External validation
- Evaluating a model on data from sites, time periods or populations different from those used to develop it.
- Calibration
- Agreement between predicted probabilities and observed outcome frequencies.
- Ambient scribe
- A tool that records a clinical conversation, transcribes it and drafts a structured note for the clinician to review.
- pLDDT
- AlphaFold's per-residue confidence score (0 to 100) estimating how reliable the predicted local structure is.
Check your understanding
- 1.
A screening model has sensitivity 0.80 and specificity 0.90 and is used where prevalence is 1%. What is its positive predictive value, approximately?
- 2.
In the Obermeyer et al. (2019) study of a care-management algorithm, what was the main source of racial bias?
- 3.
What does an FDA Predetermined Change Control Plan allow?
- 4.
Which study design gives the strongest evidence that using an AI tool improves patient outcomes?
- 5.
A chest X-ray dataset has several images per patient. A team splits images randomly into training and test sets. What is the main problem?
Exercises
Work each problem before opening the solution.
- Exercise 1Core
An AI tool for detecting a condition has sensitivity 0.85 and specificity 0.92. It will be used in a population of 10,000 people where prevalence is 2%.
- Fill in the 2×2 table (TP, FN, FP, TN).
- Compute PPV and NPV.
- How many flagged patients must clinicians evaluate, on average, to find one true case?
Show solution
Diseased: . TP ; FN .
Healthy: 9,800. FP ; TN .
Number needed to evaluate flagged patients per true case. A negative result is very reassuring; a positive result is still more likely to be wrong than right, so the workflow must budget clinician time for confirmation.
- Exercise 2Core
Write a Python function
subgroup_sensitivity(y, flag, group)that returns, for each subgroup, the number of positive cases, the sensitivity of the binaryflag, and a 95% percentile-bootstrap confidence interval. Test it on synthetic data where the true sensitivity is 0.85 in group A and 0.70 in group B.Show solution
import numpy as np def subgroup_sensitivity(y, flag, group, n_boot=2000, seed=0): """Sensitivity (recall) per subgroup with a percentile bootstrap 95% CI.""" rng = np.random.default_rng(seed) out = {} for g in np.unique(group): pos = np.where((group == g) & (y == 1))[0] # positives in this group hits = flag[pos].astype(float) boots = [rng.choice(hits, len(hits), replace=True).mean() for _ in range(n_boot)] lo, hi = np.percentile(boots, [2.5, 97.5]) out[g] = (len(pos), hits.mean(), lo, hi) return out rng = np.random.default_rng(1) n = 20000 group = rng.choice(["A", "B"], n, p=[0.8, 0.2]) y = (rng.random(n) < 0.05).astype(int) p_detect = np.where(group == "A", 0.85, 0.70) flag = np.where(y == 1, rng.random(n) < p_detect, rng.random(n) < 0.08) for g, (npos, sens, lo, hi) in subgroup_sensitivity(y, flag, group).items(): print(g, npos, round(sens, 2), round(lo, 2), round(hi, 2))The bootstrap resamples only the positive cases within each group, because sensitivity is a proportion over positives. A typical run gives about 0.85 (CI roughly 0.83–0.88, about 800 positives) for A and about 0.69 (CI roughly 0.62–0.75, about 190 positives) for B. Note how much wider B's interval is: small subgroups need more data before you can claim parity or a gap.
- Exercise 3Core
A vendor says: "Our sepsis model achieved an AUROC of 0.89 on 40,000 encounters." List the questions you would ask before deploying it, mapped to the evidence ladder in this lesson.
Show solution
- Technical (level 1): Was the 0.89 measured on a held-out set split by patient and time? What was the prediction time relative to sepsis onset (predicting after antibiotics are ordered is easy and useless)? How was sepsis defined as a label?
- External (level 2): Has it been validated at other hospitals, especially ones like ours (EHR vendor, case mix, coding practices)? What are sensitivity, PPV and alert rate at the proposed threshold, and calibration? How does performance vary by age, sex, race and ethnicity, with confidence intervals?
- Prospective (level 3): Has it run in silent mode in real time? How many alerts per unit per shift would we see?
- Impact (level 4): Is there evidence that clinicians act on alerts and that time to antibiotics or mortality improves?
- Post-market (level 5): How will we monitor performance and drift, who owns the model, and what is the plan when performance drops?
The Wong et al. (2021) external validation of a widely deployed sepsis model, which found much lower discrimination than reported, is the reason each question matters.
- Exercise 4Challenge
Your health system plans to deploy an LLM ambient scribe for outpatient visits. Design an evaluation and monitoring plan. Include: what errors to measure, how many notes to audit to estimate an error rate near 5% within ±2 percentage points at 95% confidence, who reviews, and what triggers a rollback.
Show solution
Error taxonomy (per note, reviewed against the audio or transcript): omissions of clinically relevant information; fabrications (content not said or done, such as an examination finding); misattributions (patient statements recorded as clinician findings); wrong values (medication, dose, laterality); and harmful errors (those that could change care).
Sample size. For a proportion and margin at 95% confidence ():
so audit at least 457 randomly sampled notes, stratified by specialty, language and visit type, and report rates with confidence intervals per stratum.
Process. Pilot with volunteer clinicians; trained reviewers (clinicians or clinical documentation specialists) audit the sample; clinicians remain the signing authors and must edit before signing; track edit distance and time-to-sign as secondary metrics; obtain patient consent for recording per local law and policy.
Monitoring and rollback. Continue a smaller monthly audit (for example 100 notes) after go-live; re-run the full audit after any model or vendor update. Pre-define triggers: any harmful error prompts incident review; a fabrication rate whose lower confidence bound exceeds the agreed threshold, or a significant rise after an update, triggers rollback to the previous version or manual documentation. Document everything in the governance record.
Further reading
- paperJumper et al., Highly accurate protein structure prediction with AlphaFold (2021)
- paperLam et al., Learning skillful medium-range global weather forecasting (2023)
- paperTopol, High-performance medicine: the convergence of human and artificial intelligence (2019)
- paperObermeyer, Powers, Vogeli & Mullainathan, Dissecting racial bias in an algorithm used to manage the health of populations (2019)
- paperWong et al., External validation of a widely implemented proprietary sepsis prediction model in hospitalized patients (2021)
Go further
Sources
- FDA: Artificial Intelligence-Enabled Medical Devices (list)
- King & Spalding: FDA publishes final PCCP guidance for AI-enabled device software functions (Dec 2024)
- Regulation (EU) 2017/745 on medical devices (EUR-Lex)
- Abràmoff et al., Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices (npj Digital Medicine, 2018)
- Lång et al., Artificial intelligence-supported screen reading versus standard double reading in the MASAI trial (Lancet Oncology, 2023)
- Abramson et al., Accurate structure prediction of biomolecular interactions with AlphaFold 3 (Nature, 2024)
- Nobel Prize in Chemistry 2024: press release
- Price et al., Probabilistic weather forecasting with machine learning (GenCast, Nature, 2024)
- Merchant et al., Scaling deep learning for materials discovery (GNoME, Nature, 2023)
- National Law Review: EU Digital Omnibus on AI enters into force (2026)
- Lund University: AI support in breast cancer screening leads to fewer missed cancer cases (MASAI, Jan 2026)
- ECMWF: ECMWF's AI forecasts become operational (Feb 2025)
Fact-checked and last reviewed 2026-11-05